Debug Log started at: 2024-05-11 12:08:11[2024-05-11 12:08:13:729] [] [main] VESAgentServiceRestTest INFO : No active profile set, falling back to default profiles: default [2024-05-11 12:08:18:462] [] [main] StartupTimerService DEBUG: Initializing all device connectivity check timer tasks. [2024-05-11 12:08:18:745] [] [main] StartupTimerService DEBUG: No device reachability check timer tasks exist. [2024-05-11 12:08:20:328] [] [main] VESAgentServiceRestTest INFO : Started VESAgentServiceRestTest in 8.132 seconds (JVM running for 10.259) [2024-05-11 12:08:20:385] [] [main] VESAgentService DEBUG: VES Notification request processing started [2024-05-11 12:08:20:385] [] [main] VESAgentService DEBUG: VES Notification request Fault processing started [2024-05-11 12:08:20:385] [] [main] AlarmMappingHandler DEBUG: Converting Notification to VES fault event started [2024-05-11 12:08:20:386] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.EventTime [2024-05-11 12:08:20:387] [] [main] Parser DEBUG: ADDING Device.FaultMgmt.ExpeditedEvent.1 [2024-05-11 12:08:20:387] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AlarmIdentifier [2024-05-11 12:08:20:387] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.NotificationType [2024-05-11 12:08:20:388] [] [main] ExpeditedEvent DEBUG: NotificationType is NewAlarm validated successfully [2024-05-11 12:08:20:388] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.ManagedObjectInstance [2024-05-11 12:08:20:388] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.EventType [2024-05-11 12:08:20:388] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.ProbableCause [2024-05-11 12:08:20:388] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.SpecificProblem [2024-05-11 12:08:20:388] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.PerceivedSeverity [2024-05-11 12:08:20:388] [] [main] ExpeditedEvent DEBUG: Severity is validated successfully : CRITICAL [2024-05-11 12:08:20:388] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AdditionalText [2024-05-11 12:08:20:388] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AdditionalInformation [2024-05-11 12:08:20:390] [] [main] AlarmMappingHandler DEBUG: Converting Notification to VES fault event completed :[org.commscope.tr069adapter.vesagent.model.Event@80c35a9] [2024-05-11 12:08:20:464] [] [main] VESAgentService DEBUG: VES Notification request Fault processing completed [2024-05-11 12:08:20:464] [] [main] VESAgentService DEBUG: VES Notification request processing completed [2024-05-11 12:08:20:481] [] [main] VESAgentService DEBUG: VES Notification request processing started [2024-05-11 12:08:20:481] [] [main] VESAgentService DEBUG: VES Notification request Fault processing started [2024-05-11 12:08:20:481] [] [main] AlarmMappingHandler DEBUG: Converting Notification to VES fault event started [2024-05-11 12:08:20:481] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.EventTime [2024-05-11 12:08:20:481] [] [main] Parser DEBUG: ADDING Device.FaultMgmt.ExpeditedEvent.1 [2024-05-11 12:08:20:481] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AlarmIdentifier [2024-05-11 12:08:20:481] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.NotificationType [2024-05-11 12:08:20:481] [] [main] ExpeditedEvent DEBUG: NotificationType is NewAlarm validated successfully [2024-05-11 12:08:20:481] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.ManagedObjectInstance [2024-05-11 12:08:20:482] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.EventType [2024-05-11 12:08:20:482] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.ProbableCause [2024-05-11 12:08:20:482] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.SpecificProblem [2024-05-11 12:08:20:482] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.PerceivedSeverity [2024-05-11 12:08:20:482] [] [main] ExpeditedEvent DEBUG: Severity is validated successfully : CRITICAL [2024-05-11 12:08:20:482] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AdditionalText [2024-05-11 12:08:20:482] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AdditionalInformation [2024-05-11 12:08:20:482] [] [main] AlarmMappingHandler DEBUG: Converting Notification to VES fault event completed :[org.commscope.tr069adapter.vesagent.model.Event@274e629c] [2024-05-11 12:08:20:489] [] [main] VESAgentService DEBUG: VES Notification request Fault processing completed [2024-05-11 12:08:20:490] [] [main] VESAgentService DEBUG: VES Notification request processing completed [2024-05-11 12:08:20:501] [] [main] VESAgentService DEBUG: VES Notification request processing started [2024-05-11 12:08:20:501] [] [main] VESAgentService DEBUG: VES Notification request Fault processing started [2024-05-11 12:08:20:501] [] [main] AlarmMappingHandler DEBUG: Converting Notification to VES fault event started [2024-05-11 12:08:20:501] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.EventTime [2024-05-11 12:08:20:501] [] [main] Parser DEBUG: ADDING Device.FaultMgmt.ExpeditedEvent.1 [2024-05-11 12:08:20:501] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AlarmIdentifier [2024-05-11 12:08:20:502] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.NotificationType [2024-05-11 12:08:20:502] [] [main] ExpeditedEvent DEBUG: NotificationType is NewAlarm validated successfully [2024-05-11 12:08:20:502] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.ManagedObjectInstance [2024-05-11 12:08:20:502] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.EventType [2024-05-11 12:08:20:502] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.ProbableCause [2024-05-11 12:08:20:502] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.SpecificProblem [2024-05-11 12:08:20:502] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.PerceivedSeverity [2024-05-11 12:08:20:502] [] [main] ExpeditedEvent DEBUG: Severity is validated successfully : CLEAR [2024-05-11 12:08:20:502] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AdditionalText [2024-05-11 12:08:20:502] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AdditionalInformation [2024-05-11 12:08:20:502] [] [main] AlarmMappingHandler DEBUG: Converting Notification to VES fault event completed :[org.commscope.tr069adapter.vesagent.model.Event@1da6d6d9] [2024-05-11 12:08:20:508] [] [main] VESAgentService DEBUG: VES Notification request Fault processing completed [2024-05-11 12:08:20:508] [] [main] VESAgentService DEBUG: VES Notification request processing completed [2024-05-11 12:08:20:517] [] [main] VESAgentService DEBUG: VES Notification request processing started [2024-05-11 12:08:20:517] [] [main] VESAgentService DEBUG: VES Notification request PnfRegister on container restart processing started [2024-05-11 12:08:20:517] [] [main] PnfRegMappingHandler DEBUG: Converting Notification to VES pnfevent started [2024-05-11 12:08:20:547] [] [main] PnfRegMappingHandler DEBUG: Converting Notification to VES pnfevent completed [2024-05-11 12:08:20:554] [] [main] VESAgentService DEBUG: VES Notification request processing completed [2024-05-11 12:08:20:563] [] [main] VESAgentService DEBUG: VES Notification request processing started [2024-05-11 12:08:20:564] [] [main] VESAgentService DEBUG: VES Notification request PnfRegister on container restart processing started [2024-05-11 12:08:20:564] [] [main] PnfRegMappingHandler DEBUG: Converting Notification to VES pnfevent started [2024-05-11 12:08:20:566] [] [main] PnfRegMappingHandler DEBUG: Converting Notification to VES pnfevent completed [2024-05-11 12:08:20:571] [] [main] VESAgentService DEBUG: VES Notification request processing completed [2024-05-11 12:08:20:581] [] [main] VESAgentService DEBUG: VES Notification request processing started [2024-05-11 12:08:20:581] [] [main] VESAgentService DEBUG: VES Notification request PnfRegister processing started [2024-05-11 12:08:20:581] [] [main] PnfRegMappingHandler DEBUG: Converting Notification to VES pnfevent started [2024-05-11 12:08:20:584] [] [main] PnfRegMappingHandler DEBUG: Converting Notification to VES pnfevent completed [2024-05-11 12:08:20:589] [] [main] PnfRegMappingHandler DEBUG: VES message for PnfRegistration : {"event":{"commonEventHeader":{"version":"4.0.1","vesEventListenerVersion":"7.0.1","domain":"pnfRegistration","eventName":"pnfReg_LTE_Enterprise_C-RANSC_Cntrl-ORAN","eventType":"Pnfevt","eventId":"PnfReg00005B9A11715429300581","sequence":0,"priority":"High","reportingEntityId":"00005B9A1","reportingEntityName":"0005B9A1","sourceId":"00005B9A1","sourceName":"0005B9A1","nfVendorName":"ORAN","nfNamingCode":"","nfcNamingCode":"","startEpochMicrosec":1715429300581,"lastEpochMicrosec":1715429300581},"pnfRegistrationFields":{"pnfRegistrationFieldsVersion":"2.0","serialNumber":"00005B9A1","vendorName":"ORAN","oamV4IpAddress":"10.211.5.27","oamV6IpAddress":"","unitType":"TR069","unitFamily":"ORAN","modelNumber":"LTE_Enterprise_C-RANSC_Cntrl","manufactureDate":"","macAddress":"00005B9A1","lastServiceDate":"11052024","additionalFields":{"protocol":"SSH","password":"netconf","oamPort":"17830","betweenAttemptsTimeout":"2000","keepaliveDelay":"120","sleep-factor":"1.5","reconnectOnChangedSchema":"false","connectionTimeout":"20000","maxConnectionAttempts":"100","username":"netconf","tcpOnly":"false"}}}} [2024-05-11 12:08:20:601] [] [main] HeartBeatMessageHandler INFO : Creating heartbeat records and timer using default heartbeatPeriod 5 minutes. [2024-05-11 12:08:20:686] [] [main] VESAgentService DEBUG: VES Notification request PnfRegister processing completed [2024-05-11 12:08:20:686] [] [main] VESAgentService DEBUG: VES Notification request processing completed [2024-05-11 12:08:20:695] [] [main] VESAgentService DEBUG: VES Notification request processing started [2024-05-11 12:08:20:695] [] [main] VESAgentService DEBUG: VES Notification request PnfRegister processing started [2024-05-11 12:08:20:696] [] [main] PnfRegMappingHandler DEBUG: Converting Notification to VES pnfevent started [2024-05-11 12:08:20:699] [] [main] PnfRegMappingHandler DEBUG: Converting Notification to VES pnfevent completed [2024-05-11 12:08:20:706] [] [main] PnfRegMappingHandler DEBUG: VES message for PnfRegistration : {"event":{"commonEventHeader":{"version":"4.0.1","vesEventListenerVersion":"7.0.1","domain":"pnfRegistration","eventName":"pnfReg_LTE_Enterprise_C-RANSC_Cntrl-ORAN","eventType":"Pnfevt","eventId":"PnfReg00005B9A11715429300696","sequence":0,"priority":"High","reportingEntityId":"00005B9A1","reportingEntityName":"00005B9A1","sourceId":"00005B9A1","sourceName":"00005B9A1","nfVendorName":"ORAN","nfNamingCode":"","nfcNamingCode":"","startEpochMicrosec":1715429300696,"lastEpochMicrosec":1715429300696},"pnfRegistrationFields":{"pnfRegistrationFieldsVersion":"2.0","serialNumber":"00005B9A1","vendorName":"ORAN","oamV4IpAddress":"10.211.5.27","oamV6IpAddress":"","unitType":"TR069","unitFamily":"ORAN","modelNumber":"LTE_Enterprise_C-RANSC_Cntrl","manufactureDate":"","macAddress":"00005B9A1","lastServiceDate":"11052024","additionalFields":{"protocol":"SSH","password":"netconf","oamPort":"17830","betweenAttemptsTimeout":"2000","keepaliveDelay":"120","sleep-factor":"1.5","reconnectOnChangedSchema":"false","connectionTimeout":"20000","maxConnectionAttempts":"100","username":"netconf","tcpOnly":"false"}}}} [2024-05-11 12:08:20:722] [] [main] VESAgentService DEBUG: VES Notification request PnfRegister processing completed [2024-05-11 12:08:20:722] [] [main] VESAgentService DEBUG: VES Notification request processing completed [2024-05-11 12:08:20:730] [] [main] VESAgentService DEBUG: VES Notification request processing started [2024-05-11 12:08:20:730] [] [main] VESAgentService DEBUG: VES Notification request Fault processing started [2024-05-11 12:08:20:730] [] [main] AlarmMappingHandler DEBUG: Converting Notification to VES fault event started [2024-05-11 12:08:20:730] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.EventTime [2024-05-11 12:08:20:731] [] [main] Parser DEBUG: ADDING Device.FaultMgmt.ExpeditedEvent.1 [2024-05-11 12:08:20:731] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AlarmIdentifier [2024-05-11 12:08:20:731] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.NotificationType [2024-05-11 12:08:20:731] [] [main] ExpeditedEvent DEBUG: NotificationType is NewAlarm validated successfully [2024-05-11 12:08:20:731] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.ManagedObjectInstance [2024-05-11 12:08:20:731] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.EventType [2024-05-11 12:08:20:731] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.ProbableCause [2024-05-11 12:08:20:731] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.SpecificProblem [2024-05-11 12:08:20:731] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.PerceivedSeverity [2024-05-11 12:08:20:731] [] [main] ExpeditedEvent DEBUG: Severity is validated successfully : CLEAR [2024-05-11 12:08:20:731] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AdditionalText [2024-05-11 12:08:20:731] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AdditionalInformation [2024-05-11 12:08:20:731] [] [main] AlarmMappingHandler DEBUG: Converting Notification to VES fault event completed :[org.commscope.tr069adapter.vesagent.model.Event@34400ba] [2024-05-11 12:08:20:736] [] [main] VESAgentService DEBUG: VES Notification request Fault processing completed [2024-05-11 12:08:20:737] [] [main] VESAgentService DEBUG: VES Notification request processing completed