Debug Log started at: 2026-06-20 12:08:56[2026-06-20 12:08:59:713] [] [main] VESAgentServiceRestTest INFO : No active profile set, falling back to default profiles: default [2026-06-20 12:09:07:063] [] [main] StartupTimerService DEBUG: Initializing all device connectivity check timer tasks. [2026-06-20 12:09:07:436] [] [main] StartupTimerService DEBUG: No device reachability check timer tasks exist. [2026-06-20 12:09:09:897] [] [main] VESAgentServiceRestTest INFO : Started VESAgentServiceRestTest in 12.728 seconds (JVM running for 16.085) [2026-06-20 12:09:10:001] [] [main] VESAgentService DEBUG: VES Notification request processing started [2026-06-20 12:09:10:001] [] [main] VESAgentService DEBUG: VES Notification request Fault processing started [2026-06-20 12:09:10:001] [] [main] AlarmMappingHandler DEBUG: Converting Notification to VES fault event started [2026-06-20 12:09:10:003] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.EventTime [2026-06-20 12:09:10:004] [] [main] Parser DEBUG: ADDING Device.FaultMgmt.ExpeditedEvent.1 [2026-06-20 12:09:10:004] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AlarmIdentifier [2026-06-20 12:09:10:005] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.NotificationType [2026-06-20 12:09:10:005] [] [main] ExpeditedEvent DEBUG: NotificationType is NewAlarm validated successfully [2026-06-20 12:09:10:005] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.ManagedObjectInstance [2026-06-20 12:09:10:005] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.EventType [2026-06-20 12:09:10:005] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.ProbableCause [2026-06-20 12:09:10:005] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.SpecificProblem [2026-06-20 12:09:10:006] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.PerceivedSeverity [2026-06-20 12:09:10:006] [] [main] ExpeditedEvent DEBUG: Severity is validated successfully : CRITICAL [2026-06-20 12:09:10:006] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AdditionalText [2026-06-20 12:09:10:006] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AdditionalInformation [2026-06-20 12:09:10:009] [] [main] AlarmMappingHandler DEBUG: Converting Notification to VES fault event completed :[org.commscope.tr069adapter.vesagent.model.Event@5500e9b6] [2026-06-20 12:09:10:133] [] [main] VESAgentService DEBUG: VES Notification request Fault processing completed [2026-06-20 12:09:10:134] [] [main] VESAgentService DEBUG: VES Notification request processing completed [2026-06-20 12:09:10:160] [] [main] VESAgentService DEBUG: VES Notification request processing started [2026-06-20 12:09:10:160] [] [main] VESAgentService DEBUG: VES Notification request Fault processing started [2026-06-20 12:09:10:160] [] [main] AlarmMappingHandler DEBUG: Converting Notification to VES fault event started [2026-06-20 12:09:10:160] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.EventTime [2026-06-20 12:09:10:160] [] [main] Parser DEBUG: ADDING Device.FaultMgmt.ExpeditedEvent.1 [2026-06-20 12:09:10:160] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AlarmIdentifier [2026-06-20 12:09:10:160] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.NotificationType [2026-06-20 12:09:10:160] [] [main] ExpeditedEvent DEBUG: NotificationType is NewAlarm validated successfully [2026-06-20 12:09:10:160] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.ManagedObjectInstance [2026-06-20 12:09:10:161] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.EventType [2026-06-20 12:09:10:161] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.ProbableCause [2026-06-20 12:09:10:161] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.SpecificProblem [2026-06-20 12:09:10:161] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.PerceivedSeverity [2026-06-20 12:09:10:161] [] [main] ExpeditedEvent DEBUG: Severity is validated successfully : CRITICAL [2026-06-20 12:09:10:161] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AdditionalText [2026-06-20 12:09:10:161] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AdditionalInformation [2026-06-20 12:09:10:161] [] [main] AlarmMappingHandler DEBUG: Converting Notification to VES fault event completed :[org.commscope.tr069adapter.vesagent.model.Event@7fb84cba] [2026-06-20 12:09:10:173] [] [main] VESAgentService DEBUG: VES Notification request Fault processing completed [2026-06-20 12:09:10:174] [] [main] VESAgentService DEBUG: VES Notification request processing completed [2026-06-20 12:09:10:187] [] [main] VESAgentService DEBUG: VES Notification request processing started [2026-06-20 12:09:10:187] [] [main] VESAgentService DEBUG: VES Notification request Fault processing started [2026-06-20 12:09:10:187] [] [main] AlarmMappingHandler DEBUG: Converting Notification to VES fault event started [2026-06-20 12:09:10:188] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.EventTime [2026-06-20 12:09:10:188] [] [main] Parser DEBUG: ADDING Device.FaultMgmt.ExpeditedEvent.1 [2026-06-20 12:09:10:188] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AlarmIdentifier [2026-06-20 12:09:10:188] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.NotificationType [2026-06-20 12:09:10:188] [] [main] ExpeditedEvent DEBUG: NotificationType is NewAlarm validated successfully [2026-06-20 12:09:10:188] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.ManagedObjectInstance [2026-06-20 12:09:10:188] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.EventType [2026-06-20 12:09:10:188] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.ProbableCause [2026-06-20 12:09:10:188] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.SpecificProblem [2026-06-20 12:09:10:188] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.PerceivedSeverity [2026-06-20 12:09:10:188] [] [main] ExpeditedEvent DEBUG: Severity is validated successfully : CLEAR [2026-06-20 12:09:10:188] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AdditionalText [2026-06-20 12:09:10:188] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AdditionalInformation [2026-06-20 12:09:10:188] [] [main] AlarmMappingHandler DEBUG: Converting Notification to VES fault event completed :[org.commscope.tr069adapter.vesagent.model.Event@2426d1c6] [2026-06-20 12:09:10:199] [] [main] VESAgentService DEBUG: VES Notification request Fault processing completed [2026-06-20 12:09:10:199] [] [main] VESAgentService DEBUG: VES Notification request processing completed [2026-06-20 12:09:10:210] [] [main] VESAgentService DEBUG: VES Notification request processing started [2026-06-20 12:09:10:210] [] [main] VESAgentService DEBUG: VES Notification request PnfRegister on container restart processing started [2026-06-20 12:09:10:210] [] [main] PnfRegMappingHandler DEBUG: Converting Notification to VES pnfevent started [2026-06-20 12:09:10:266] [] [main] PnfRegMappingHandler DEBUG: Converting Notification to VES pnfevent completed [2026-06-20 12:09:10:284] [] [main] VESAgentService DEBUG: VES Notification request processing completed [2026-06-20 12:09:10:295] [] [main] VESAgentService DEBUG: VES Notification request processing started [2026-06-20 12:09:10:295] [] [main] VESAgentService DEBUG: VES Notification request PnfRegister on container restart processing started [2026-06-20 12:09:10:296] [] [main] PnfRegMappingHandler DEBUG: Converting Notification to VES pnfevent started [2026-06-20 12:09:10:299] [] [main] PnfRegMappingHandler DEBUG: Converting Notification to VES pnfevent completed [2026-06-20 12:09:10:312] [] [main] VESAgentService DEBUG: VES Notification request processing completed [2026-06-20 12:09:10:388] [] [main] VESAgentService DEBUG: VES Notification request processing started [2026-06-20 12:09:10:389] [] [main] VESAgentService DEBUG: VES Notification request PnfRegister processing started [2026-06-20 12:09:10:389] [] [main] PnfRegMappingHandler DEBUG: Converting Notification to VES pnfevent started [2026-06-20 12:09:10:397] [] [main] PnfRegMappingHandler DEBUG: Converting Notification to VES pnfevent completed [2026-06-20 12:09:10:405] [] [main] PnfRegMappingHandler DEBUG: VES message for PnfRegistration : {"event":{"commonEventHeader":{"version":"4.0.1","vesEventListenerVersion":"7.0.1","domain":"pnfRegistration","eventName":"pnfReg_LTE_Enterprise_C-RANSC_Cntrl-ORAN","eventType":"Pnfevt","eventId":"PnfReg00005B9A11781957350389","sequence":0,"priority":"High","reportingEntityId":"00005B9A1","reportingEntityName":"0005B9A1","sourceId":"00005B9A1","sourceName":"0005B9A1","nfVendorName":"ORAN","nfNamingCode":"","nfcNamingCode":"","startEpochMicrosec":1781957350389,"lastEpochMicrosec":1781957350389},"pnfRegistrationFields":{"pnfRegistrationFieldsVersion":"2.0","serialNumber":"00005B9A1","vendorName":"ORAN","oamV4IpAddress":"10.211.5.27","oamV6IpAddress":"","unitType":"TR069","unitFamily":"ORAN","modelNumber":"LTE_Enterprise_C-RANSC_Cntrl","manufactureDate":"","macAddress":"00005B9A1","lastServiceDate":"20062026","additionalFields":{"protocol":"SSH","password":"netconf","oamPort":"17830","betweenAttemptsTimeout":"2000","keepaliveDelay":"120","sleep-factor":"1.5","reconnectOnChangedSchema":"false","connectionTimeout":"20000","maxConnectionAttempts":"100","username":"netconf","tcpOnly":"false"}}}} [2026-06-20 12:09:10:424] [] [main] HeartBeatMessageHandler INFO : Creating heartbeat records and timer using default heartbeatPeriod 5 minutes. [2026-06-20 12:09:10:560] [] [main] VESAgentService DEBUG: VES Notification request PnfRegister processing completed [2026-06-20 12:09:10:560] [] [main] VESAgentService DEBUG: VES Notification request processing completed [2026-06-20 12:09:10:574] [] [main] VESAgentService DEBUG: VES Notification request processing started [2026-06-20 12:09:10:575] [] [main] VESAgentService DEBUG: VES Notification request PnfRegister processing started [2026-06-20 12:09:10:575] [] [main] PnfRegMappingHandler DEBUG: Converting Notification to VES pnfevent started [2026-06-20 12:09:10:582] [] [main] PnfRegMappingHandler DEBUG: Converting Notification to VES pnfevent completed [2026-06-20 12:09:10:589] [] [main] PnfRegMappingHandler DEBUG: VES message for PnfRegistration : {"event":{"commonEventHeader":{"version":"4.0.1","vesEventListenerVersion":"7.0.1","domain":"pnfRegistration","eventName":"pnfReg_LTE_Enterprise_C-RANSC_Cntrl-ORAN","eventType":"Pnfevt","eventId":"PnfReg00005B9A11781957350576","sequence":0,"priority":"High","reportingEntityId":"00005B9A1","reportingEntityName":"00005B9A1","sourceId":"00005B9A1","sourceName":"00005B9A1","nfVendorName":"ORAN","nfNamingCode":"","nfcNamingCode":"","startEpochMicrosec":1781957350576,"lastEpochMicrosec":1781957350576},"pnfRegistrationFields":{"pnfRegistrationFieldsVersion":"2.0","serialNumber":"00005B9A1","vendorName":"ORAN","oamV4IpAddress":"10.211.5.27","oamV6IpAddress":"","unitType":"TR069","unitFamily":"ORAN","modelNumber":"LTE_Enterprise_C-RANSC_Cntrl","manufactureDate":"","macAddress":"00005B9A1","lastServiceDate":"20062026","additionalFields":{"protocol":"SSH","password":"netconf","oamPort":"17830","betweenAttemptsTimeout":"2000","keepaliveDelay":"120","sleep-factor":"1.5","reconnectOnChangedSchema":"false","connectionTimeout":"20000","maxConnectionAttempts":"100","username":"netconf","tcpOnly":"false"}}}} [2026-06-20 12:09:10:614] [] [main] VESAgentService DEBUG: VES Notification request PnfRegister processing completed [2026-06-20 12:09:10:618] [] [main] VESAgentService DEBUG: VES Notification request processing completed [2026-06-20 12:09:10:647] [] [main] VESAgentService DEBUG: VES Notification request processing started [2026-06-20 12:09:10:647] [] [main] VESAgentService DEBUG: VES Notification request Fault processing started [2026-06-20 12:09:10:647] [] [main] AlarmMappingHandler DEBUG: Converting Notification to VES fault event started [2026-06-20 12:09:10:647] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.EventTime [2026-06-20 12:09:10:647] [] [main] Parser DEBUG: ADDING Device.FaultMgmt.ExpeditedEvent.1 [2026-06-20 12:09:10:647] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AlarmIdentifier [2026-06-20 12:09:10:647] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.NotificationType [2026-06-20 12:09:10:647] [] [main] ExpeditedEvent DEBUG: NotificationType is NewAlarm validated successfully [2026-06-20 12:09:10:648] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.ManagedObjectInstance [2026-06-20 12:09:10:648] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.EventType [2026-06-20 12:09:10:648] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.ProbableCause [2026-06-20 12:09:10:648] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.SpecificProblem [2026-06-20 12:09:10:648] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.PerceivedSeverity [2026-06-20 12:09:10:648] [] [main] ExpeditedEvent DEBUG: Severity is validated successfully : CLEAR [2026-06-20 12:09:10:648] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AdditionalText [2026-06-20 12:09:10:648] [] [main] Parser DEBUG: PARAM NAME Device.FaultMgmt.ExpeditedEvent.1.AdditionalInformation [2026-06-20 12:09:10:649] [] [main] AlarmMappingHandler DEBUG: Converting Notification to VES fault event completed :[org.commscope.tr069adapter.vesagent.model.Event@4c25f762] [2026-06-20 12:09:10:655] [] [main] VESAgentService DEBUG: VES Notification request Fault processing completed [2026-06-20 12:09:10:655] [] [main] VESAgentService DEBUG: VES Notification request processing completed